  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-04-22",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "status": "Terminated",
      "city": "Mountain View",
      "state": "CA",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "68195",
      "recalling_firm": "Siemens Medical Solutions USA, Inc.",
      "address_1": "685 E Middlefield Rd",
      "address_2": "",
      "postal_code": "94043-4045",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "Worldwide Distribution - USA including the states of AL, AZ, AR, CA, CO, CT, FL, GA, ID, IL, IN, KS, LS, MD, MI, MN, MO, NH, NY, NC, OH, OR, PA, SC, SD, TN, TX, UT, VA, WA and WI.,  and the countries of Australia, Austria, Dominican Rep, France, Germany, Iceland, India, Indonesia, Ireland, Israel, Italy, Japan, Mexico, New Zealand, Norway, Philippines, Poland, Portugal, Republic Korea, Romania, Russian Fed, Saudi Arabia, Sweden, Switzerland, Turkey, U.A.E. and United Kingdom.",
      "recall_number": "Z-1667-2014",
      "product_description": "ACUSON SC2000 Ultrasound Systems with software version 3.5 (VA35);  ultrasound imaging system.",
      "product_quantity": "257 units",
      "reason_for_recall": "Software issues with ACUSON SC2000 ultrasound with software version 3/5 (VA35) -  may incorrectly display the color flow data in the wrong position and when Doppler Frequency is adjusted, the system does not restart the pulsed wave Doppler or continuous wave Doppler waveform.",
      "recall_initiation_date": "20140423",
      "center_classification_date": "20140528",
      "termination_date": "20151112",
      "report_date": "20140604",
      "code_info": "Model number 10433816; Serial numbers: US:  400290  400425  400439  400441  400443  400447  401176  401591  400763  400787  400789  400790  400791  400792  400794  400797  400063  400860  400868  400872  400873  400877  401041  401187  401441  401540  401590  401602  401662  401696  401638  401641  400174  400882  401612  401501  401507  401561  401378  400297  401423  401429  401550  401491  401494  401562  401572  401584  401621  400803  400821  400570  401010  401020  401235  401252  401564  401611  400998  400999  401601  401648  400979  401625  401631  400234  400312  400972  401433  400336  401645  400108  400177  400203  400313  400650  400663  400664  400176  400712  400716  401565  400128  400142  400782  400887  400889  401043  401554  400067  401257  401320  401559  401576  401633  401583  400875  400912  400925  400474  400902  401387  401476  401477  401547  401496  401567  401569  401570  401597  401607  401608  401618  401669  400630  401558  401587  401644  400227  400473  400577  400649  401294  401600  401596  ROW:  400652  400733  400737  400746  401437  401443  401478  401495  401188  401191  401650  400546  400945  401506  401371  401325  401393  401403  401543  401571  401580  401581  401613  401620  401623  400302  400348  400347  400553  400558  400726  400995  400996  401120  401123  401209  401260  401288  401338  401344  401442  401452  401551  401555  401556  401522  401560  401577  401579  401588  401589  401603  401604  401606  401643  401699  401630  401676  400125  400200  401434  401658  401661  401626  401435  401498  401217  401389  401431  401563  401585  401605  401687  400155  400180  400307  400704  401428  401451  401541  401521  401582  401594  401595  401624  401632  401637  401640  401666  401688  401689  401695  401004  401508  401546  401519  401627  400247  400263  400511  401045  400497  401664  400284  400252  401566  401502  400655  400214  401394  401367  401617  401634  401651  401652  401657  401659  401663  401665  401681  401685  401686  401694  401698  400253  400836  400840  401118  400218  400990  401127  40118. 0",
      "more_code_info": ""
    }
  ]
}