  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-04-01",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "status": "Terminated",
      "city": "Stockholm",
      "state": "N/A",
      "country": "Sweden",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "87868",
      "recalling_firm": "RAYSEARCH LABORATORIES AB",
      "address_1": "Sveavagen 9",
      "address_2": "N/A",
      "postal_code": "N/A",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "E-Mail",
      "distribution_pattern": "Domestic: TN",
      "recall_number": "Z-1598-2021",
      "product_description": "RayStation standalone software radiation therapy treatment planning system.  Model Number: 8A, 8B, 9A, 9B, 10A, 10B including some service packs",
      "product_quantity": "N/A",
      "reason_for_recall": "When using more than one plan in a treatment course, the \u001cTotal dose\u001d display in Dose tracking may be incorrect. There may be a mismatch between the fractions that appear as selected in the Treatment course list in Dose tracking and the fractions that are included in the dose summation. The issue only affects RayTreat users and only the \u001cTotal dose\u001d option. \u001cAccumulation\u001d and other options  in Dose tracking are correct.",
      "recall_initiation_date": "20210407",
      "center_classification_date": "20210514",
      "termination_date": "20230602",
      "report_date": "20210526",
      "code_info": "Software version number:  8.0.0.6 ,  8.0.1.10 ,  8.1.0.47 ,  8.1.1.8 ,  8.1.2.5 ,  9.0.0.113 ,  9.1.0.933 ,  9.2.0.483 ,  10.0.0.1154 ,  10.0.1.52 ,  10.1.0.613"
    }
  ]
}