  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-04-22",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "country": "United States",
      "city": "Barrington",
      "address_1": "540 W Northwest Hwy",
      "reason_for_recall": "If environment variables  MICRO_CORRECT_MSG_TYPE  and CORRECT_MSG_TYPE are set to different values, in Microbiology result entry when released results (Final Report released) are changed and the Corrected Result messages are edited on the free-text form, some of the originally entered panel free-text is lost. For this issue to occur the original result must be amended and the environmental variabl",
      "address_2": "",
      "product_quantity": "9 Units",
      "code_info": "Software Versions 3.3, 4.0, and 4.1",
      "center_classification_date": "20130624",
      "distribution_pattern": "Worldwide Distribution - US Distribution  including the states of OH, NY, GA, TX, TN and MN and the countries of Australia, Qatar and England",
      "state": "IL",
      "product_description": "The Centricity Laboratory System is intended to be an information system designed to support the clinical and administrative activities associated with the provision and utilization of clinical laboratory services and facilities, e.g., the storing and delivering of analytical results. It is a specially designed data program application (software), which is supplied for installation in existing mainframe or decentralized computers or a computer network. This software system will not be the software directly used to run, steer, or control any specific laboratory analyzer or equipment. It is intended for use in laboratory facilities, including a central laboratory or in a multiple laboratory environment servicing satellite laboratories, reference laboratories, clinics, etc. Centricity Laboratory System is not intended for direct patient contact.",
      "report_date": "20130703",
      "classification": "Class II",
      "openfda": {},
      "recalling_firm": "GE Healthcare It",
      "recall_number": "Z-1585-2013",
      "initial_firm_notification": "Letter",
      "product_type": "Devices",
      "event_id": "64789",
      "termination_date": "20160610",
      "more_code_info": "",
      "recall_initiation_date": "20121120",
      "postal_code": "60010-3051",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "status": "Terminated"
    }
  ]
}