  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-04-01",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "status": "Ongoing",
      "city": "Miami Lakes",
      "state": "FL",
      "country": "United States",
      "classification": "Class I",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "87456",
      "recalling_firm": "Heartware, Inc.",
      "address_1": "14400 Nw 60th Ave",
      "address_2": "N/A",
      "postal_code": "33014-2807",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "Worldwide distribution: US (nationwide) and countries of: ARGENTINA, Armenia,  Australia, AUSTRIA, Bahrain, BELGIUM, Brazil, CANADA, Chile, Colombia, Croatia, Czech Republic, Denmark, Egypt, Estonia, FINLAND, France, GERMANY, Greece, Hong Kong, Hungary, INDIA, Israel, Italy, Japan, Kazakhstan, Korea, Kuwait, Latvia, LEBANON, LITHUANIA, Luxembourg, Macedonia, Malaysia, NETHERLANDS, NEW ZEALAND, Norway, POLAND, Qatar, Romania, SAUDI ARABIA, Serbia, Singapore, SLOVAKIA, SOUTH AFRICA  Spain, SWEDEN, SWITZERLAND, Taiwan, TURKEY, Ukraine, United Arab, Emirates, United Kingdom, and VIETNAM.",
      "recall_number": "Z-1426-2021",
      "product_description": "Instructions for Use and Patient Manual for HeartWare HVAD System. Accompanies these system components:  HVAD Sterile Implant Kit, Model Numbers:  1100, 1101, 1102, 1103, 1104, 1104JP, 1205, MCS1705PU  HVAD Controller Kit, Model Numbers: 1403US, 1407AU, 1407CA, 1407CH, 1407DE, 1407GB, 1407IL, 1407IN, 1407IT, 1407JP, 1407KR, 1420, 1420JP  HVAD AC Adapter Controller, Model Numbers: 1430AR, 1430AU, 1430CA, 1430CH, 1430DE, 1430GB, 1430IL, 1430IN, 1430IT, 1430JP, 1430US  HVAD DC Adapter Controller: Model Number: 1440  HVAD DATA CABLE 1575- MONITOR, Model Number: 1575  HVAD Battery Pack, Model Numbers: 1650, 1650CA-CLIN, 1650DE  HeartWare Patient Pack, Model Number: 1475  HeartWare Waist Pack, Model Numbers: 2050, 2050IL, 2050OUS  HeartWare Shoulder Pack, Model Numbers: 2060, 2060IL, 2060OUS    The HeartWare HVAD System is indicated for hemodynamic support in patients with advanced, refractory left ventricular heart failure; either as a Bridge to Cardiac Transplantation (BTT), myocardial recovery, or as Destination Therapy (DT) in patients for whom subsequent transplantation is not planned.",
      "product_quantity": "23123 devices (11292 US)",
      "reason_for_recall": "Medtronic HeartWare HVAD System Instructions for Use (IFU) and Patient Manual (PM) updates regarding: Carrying Cases, Driveline Cover Orientation, and Controller Power Up Sequence issues. The PM is being updated to clarify use of the support strap and wear instructions in addition to cleaning instructions of the carrying cases. The IFU and PM are being updated to add a useful life for the carrying cases. The PM is being updated to inform users to keep the driveline cover on when disconnecting and reconnecting the driveline. The IFU and PM are being updated to clarify the power-up sequence that causes the alarm indicator LEDs and both sets of battery LEDs to turn red for 2.5 seconds while the LCD displays the power-on message. NOTE: this update is included in the February 2021 Urgent Medical Device Notice also covered in recalls 87603 and 87604",
      "recall_initiation_date": "20210226",
      "center_classification_date": "20210416",
      "report_date": "20210428",
      "code_info": "All serial numbers",
      "more_code_info": ""
    }
  ]
}