  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-04-15",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "status": "Terminated",
      "city": "Billings",
      "state": "MT",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "76280",
      "recalling_firm": "Windstone Medical Packaging, Inc.",
      "address_1": "1602 4th Ave N",
      "address_2": "N/A",
      "postal_code": "59101-1521",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Two or more of the following: Email, Fax, Letter, Press Release, Telephone, Visit",
      "distribution_pattern": "Distributed in AZ, CA, CO, CT, FL, GA, IL, IN, KS, LA, MA, MD, MI, MN, MO, NC, ND, NE, NJ, NV, OH, PA, TX, UT, VA, and WA.",
      "recall_number": "Z-1267-2017",
      "product_description": "Basic Pack, part number AMS1868(B  Basic Pack, part number AMS2608(A  Basic Pack, part number AMS3861  Basic Pack, part number AMS4309  Basic Pack, part number PSS1833  Basic Pack, part number PSS1833(A  Basic Pack, part number PSS1848(A",
      "product_quantity": "2388 kits",
      "reason_for_recall": "The Medtronic COVER LIGHT HANDLE DISPOSABLE GLOVES of the custom Aligned Medical Solutions (AMS) kits were recalled because gloves may contain splits or holes compromising sterility.",
      "recall_initiation_date": "20170111",
      "center_classification_date": "20170228",
      "termination_date": "20170503",
      "report_date": "20170308",
      "code_info": "Lot number and expiration date    100394, 9/15/2019  100593, 9/21/2019  100594, 10/5/2019  101063, 10/15/2019  101304, 10/23/2019  83725, 6/8/2018  84749, 9/11/2018  85159, 8/1/2018  85635, 8/6/2018  85810, 7/19/2018  86252, 9/2/2018  86440, 8/7/2018  86859, 8/18/2018  86939, 11/22/2018  87105, 9/15/2018  87269, 9/30/2018  87351, 9/15/2018  87447, 11/11/2018  87942, 9/23/2018  88172, 12/3/2018  88282, 9/7/2018  88368, 9/5/2018  88846, 12/11/2018  88887, 12/7/2018  89004, 10/8/2018  89160, 12/1/2018  89438, 11/22/2018  89512, 10/9/2018  89716, 1/9/2019  89743, 12/3/2018  89811, 12/1/2018  94572, 12/15/2018  94705, 12/15/2018  94751, 1/4/2019  94853, 1/27/2019  94935, 1/25/2019  95293, 1/26/2019  95412, 1/25/2019  95936, 1/11/2019  95974, 5/29/2019  96023, 1/16/2019  96255, 1/2/2019  96410, 3/7/2019  96566, 3/9/2019  96678, 5/24/2019  96913, 5/22/2019  97124, 5/12/2019  97410, 6/3/2019  97577, 5/1/2019  97780, 6/15/2019  98017, 6/29/2019  98312, 6/24/2019  98478, 6/29/2019  98502, 6/6/2019  98663, 6/28/2019  98633, 6/30/2019  99172, 6/12/2019  99581, 6/27/2019  99703, 9/27/2019  99843, 9/30/2019  99887, 9/11/2019  99913, 9/23/2019",
      "more_code_info": ""
    }
  ]
}