      "status": "Terminated",
      "city": "Mercedita",
      "state": "PR",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "72900",
      "recalling_firm": "Zimmer Manufacturing B.V.",
      "address_1": "Turpeaux Industrial Park Rd 1 km 123.4",
      "address_2": "",
      "postal_code": "00715",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "US Nationwide Distribution",
      "recall_number": "Z-1130-2016",
      "product_description": "Product 32 consists of all product under  product code: HWC and same usage:  Item no:\t  47115401200\tHERBERT BONE SCREW, 3.0MM  47115401400\tHERBERT BONE SCREW, 3.0MM  47115401600\tHERBERT BONE SCREW, 3.0MM  47115401800\tHERBERT BONE SCREW, 3.0MM  47115402000\tHERBERT BONE SCREW, 3.0MM  47115402200\tHERBERT BONE SCREW, 3.0MM  47115402400\tHERBERT BONE SCREW, 3.0MM  47115402600\tHERBERT BONE SCREW, 3.0MM  47115402800\tHERBERT BONE SCREW, 3.0MM  47115403000\tHERBERT BONE SCREW, 3.0MM  47115502505\tHERBERT CANNULATED BONE S  47115503005\tHERBERT CANNULATED BONE S  47115503505\tHERBERT CANNULATED BONE S  47115504005\tHERBERT CANNULATED BONE S  47115504007\tHERBERT CANNULATED BONE S  47115504505\tHERBERT CANNULATED BONE S  47115504507\tHERBERT CANNULATED BONE S  47115505005\tHERBERT CANNULATED BONE S  47115505007\tHERBERT CANNULATED BONE S  47115505505\tHERBERT CANNULATED BONE S  47115505507\tHERBERT CANNULATED BONE S  47115506005\tHERBERT CANNULATED BONE S  47115506007\tHERBERT CANNULATED BONE S  47115506505\tHERBERT CANNULATED BONE S  47115506507\tHERBERT CANNULATED BONE S  47115507005\tHERBERT CANNULATED BONE S  47115507007\tHERBERT CANNULATED BONE S  47115507505\tHERBERT CANNULATED BONE S  47115507507\tHERBERT CANNULATED BONE S  47115508005\tHERBERT CANNULATED BONE S  47115508007\tHERBERT CANNULATED BONE S  47115508505\tHERBERT CANNULATED BONE S  47115508507\tHERBERT CANNULATED BONE S  47115509005\tHERBERT CANNULATED BONE S  47115509007\tHERBERT CANNULATED BONE S  47115509505\tHERBERT CANNULATED BONE S  47115509507\tHERBERT CANNULATED BONE S  47115510005\tHERBERT CANNULATED BONE S  47115510007\tHERBERT CANNULATED BONE S  115001000\tHERBERT MINI BONE SCREW 2  115001200\tHERBERT MINI BONE SCREW 2  115001400\tHERBERT MINI BONE SCREW 2  115001600\tHERBERT MINI BONE SCREW 2  115001800\tHERBERT MINI BONE SCREW 2  115002000\tHERBERT MINI BONE SCREW 2  115002200\tHERBERT MINI BONE SCREW 2  115002400\tHERBERT MINI BONE SCREW 2  115201200\tHERBERT/WHIPPLE CANN BONE  115201400\tHERBERT/WHIPPLE CANN BONE  115201600\tHERBERT/WHIPPLE CANN BONE  115201800\tHERBERT/WHIPPLE CANN BONE  115202000\tHERBERT/WHIPPLE CANN BONE  115202200\tHERBERT/WHIPPLE CANN BONE  115202400\tHERBERT/WHIPPLE CANN BONE  115202600\tHERBERT/WHIPPLE CANN BONE  115202800\tHERBERT/WHIPPLE CANN BONE  115203000\tHERBERT/WHIPPLE CANN BONE    Product Usage:  A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.",
      "product_quantity": "4018",
      "reason_for_recall": "As a result of the insufficient sealer calibration data for product packaged in firm's Building II between August 2010 and April 2013.  The affected products are sterile.",
      "recall_initiation_date": "20160111",
      "center_classification_date": "20160312",
      "termination_date": "20170413",
      "report_date": "20160323",
      "code_info": "lot no.:  61849585  61912445  61912446  61849586  61849587  61912447  61912448  61941352  61827182  61849582  62024187  62153287  61774747  61827165  61827167  61849584  61904625  61928623  62024188  62024188N  61827172  61827173  61865263  61865265  61904627  61912468  62024189  62031681  62211067  62024189N  61827157  61870904  61904626  61928624  62024190  62145270  62160893  61811070  61827193  61870905  61944998  62024191  62031682  62145271  62153288  62180565  61827151  61840634  61928627  61928628  62031639  62145272  62160895  61870906  61900329  62031646  62180567  61789465  61811156  61840635  61895711  61895713  61895714  61912679  61912682  61912691  61912694  61912695  61912699  61644731  61785346  61855921  61906705  62161934  61660596  61799289  61865276  61906699  61960093  61960095  62017439  62072611  62129843  62180552  62180552N  61660597  61865277  61865278  61936609  61936613  61963653  61988334  62017440  62027372  62040734  62112691  62138496  62142211  62328120  61660601  61799283  61799285  61835773  61865279  61906706  61936621  61936623  61981198  61981199  61981201  62009804  62027373  62086218  62097341  62112695  62198887  62258967  62027374  62027374N  61799286  61835774  61887206  61906707  61978705  61978706  62008674  62065599  62086222  62112699  62187870  62328128  61988338  61612598  61660607  61788245  61843085  61865281  61906701  61968182  61968183  62008675  62086226  62097343  62187869  62198874  62258968  61988351  62180554  61819964  61880819  61968184  62017438  62086230  62138499  62223009  61914885  62069022  61612601  61887207  61968185  62053620  62112701  62198875  61955489  62027384  61968186  62040193  62161936  61887209  61946364  62005539  62129844  62198877  61685418  61988350  62085978  61865282  61988337  62027385  62097346  61923065  62065601  61887210  61978707  62005540  62072612  61946365  62072613  61887212  61960099  61963652  62072614  62198878  62204637  62097339  61887213  61978710  62053628  62161940  61799296  62005538  61923068  62053629  62138505  62204640  62304903  62304903N  62008676  61788253  62017441  61774750  61906704  61923071  62129845  62161957  62328136  61840636  62069021  62180559  61840639  62153285  61635183  61944996  62198879  61915566  62103709  62304798  61944997  62103708  62153286  62198882  61919343  62019689  62146161  61660577  61777801  61919344  62019685  62103711  62198883  62328137  61664837  61777802  61915567  62019692  62180561  62198885  61811065  61873034  62069020  62103713  62141641  62165346  62197616  62210960  61804519  61811078  61849807  61887195  61993279  62072604  62072605  62142180  62187532  62304821  62304821N  61804520  61811152  61851962  61882672  61897689  61980116  62006416  62040561  62072606  62072607  62110004  62134893  62187535  62211064  61635186  61640832  61707780  61825947  61825949  61851966  61851968  61882676  61934178  61934182  61952701  61990341  62033050  62052729  62052731  62110006  62187537  62197617  62211065  62326527  62326527N  61804524  61804525  61825952  61825953  61825954  61851971  61867102  61887198  61897690  61897691  61934184  61934186  61980117  61980118  61990343  62006417  62006418  62065595  62072608  62072609  62072610  62110007  62134896  62134897  62160888  62187547  62204641  62223014  62258984  61640834  61750821  61754464  61789464  61825955  61839816  61851974  61867103  61882674  61887201  61919346  61919348  61934188  61974386  61974387  61990346  61999821  61999822  62052727  62052728  62065593  62097845  62097846  62097848  62103726  62160889  62160890  62165347  62197618  62204643  62239553  62354446  61764291  61764337  61764338  61839817  61851977  61867104  61867105  61887203  61919355  61919357  61934191  61993280  61993281  61999823  61999824  62080380  62080383  62110008  62110009  62160891  62176427  62204645  62258985  62304868  62304868N  61616164  61777805  61825956  61851982  61867106  61887204  61934193  61952702  61952703  61999825  61999826  62080385  62080387  62080388  62080390  62142192  62176428  62187549  62211066  62271596  61777806  61804530  61825957  61851987  61867107  61952704  61952705  61990361  62006419  62065594  62095716  62103714  62144990  62176429  61777807  61789479  61789484  61825958  61839813  61839815  61851988  61867108  61867109  61867110  61919351  61919353  61952706  61952707  61980119  61980120  61980122  62006420  62006421  62065592  62085423  62085426  62085427  62085428  62110005  62142327  62142328  62187552  62223015",
      "more_code_info": ""
    }
  ]
}