      "status": "Terminated",
      "city": "Rochester",
      "state": "NY",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "64577",
      "recalling_firm": "Ortho-Clinical Diagnostics",
      "address_1": "100 Indigo Creek Dr",
      "address_2": "N/A",
      "postal_code": "14626-5101",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "Worldwide Distribution- USA (nationwide) including Puerto Rico and countries of: Australia, Brazil, Canada, Chile, China, Colombia, England, France, Germany, India, Italy, Japan, Republic of Panama, Singapore, Spain, and Venezuela.",
      "recall_number": "Z-1108-2013",
      "product_description": "VITROS 5600 Integrated System, Product Code 6802413.    Intended for use in the measurement of a variety of chemistry analytes.",
      "product_quantity": "USA: 775 units, Foreign: 800 units",
      "reason_for_recall": "Ortho-Clinical Diagnostics, Inc. (OCD) determined that extension springs on some VITROS¿ Systems may be  out of its manufacturing specifications. Extension springs are part of the slide alignment guide assembly.  During an internal evaluation in its  manufacturing facility, it was discovered that an extension spring had insufficient force.  If the extension spring does not provide sufficient force, MicroSlides may not be properly positioned within the  MicroSlide incubator which has the potential to cause imprecise results.  Extension springs are just one  component in the slide alignment assembly.  OCD's  evaluation determined that the probability of an out of  specification extension spring alone adversely affecting results is unlikely.",
      "recall_initiation_date": "20130207",
      "center_classification_date": "20130413",
      "termination_date": "20170420",
      "report_date": "20130424",
      "code_info": "Serial Numbers 56000118 through 56001583"
    }
  ]
}