{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-04-22",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "status": "Terminated",
      "city": "Rochester",
      "state": "NY",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "64577",
      "recalling_firm": "Ortho-Clinical Diagnostics",
      "address_1": "100 Indigo Creek Dr",
      "address_2": "N/A",
      "postal_code": "14626-5101",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "Worldwide Distribution- USA (nationwide) including Puerto Rico and countries of: Australia, Brazil, Canada, Chile, China, Colombia, England, France, Germany, India, Italy, Japan, Republic of Panama, Singapore, Spain, and Venezuela.",
      "recall_number": "Z-1107-2013",
      "product_description": "VITROS 4600 Chemistry System (VITROS 5,1 FS System family member), Product Code 6802445.    Intended for use in the measurement of a variety of chemistry analytes.",
      "product_quantity": "USA: 58 units, Foreign: 103 units",
      "reason_for_recall": "Ortho-Clinical Diagnostics, Inc. (OCD) determined that extension springs on some VITROS¿ Systems may be  out of its manufacturing specifications. Extension springs are part of the slide alignment guide assembly.  During an internal evaluation in its manufacturing facility, it was discovered that an extension spring had insufficient force.  If the extension spring does not provide sufficient force, MicroSlides may not be properly positioned within the  MicroSlide incubator which has the potential to cause imprecise results.  Extension springs are just one  component in the slide alignment assembly.  OCD's  evaluation determined that the probability of an out of  specification extension spring alone adversely affecting results is unlikely.",
      "recall_initiation_date": "20130207",
      "center_classification_date": "20130413",
      "termination_date": "20170420",
      "report_date": "20130424",
      "code_info": "Serial Numbers 46000108 through 46000217"
    }
  ]
}