      "status": "Terminated",
      "city": "Redwood City",
      "state": "CA",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "72687",
      "recalling_firm": "Cardica, Inc.",
      "address_1": "900 Saginaw Dr",
      "address_2": "N/A",
      "postal_code": "94063-4753",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "Worldwide Distribution -- USA, distributed to the states of Alabama, California, Colorado, Florida, Georgia, Iowa, Massachusetts, Maryland, Minnesota, New York, Ohio, Pennsylvania, Rhode Island, Texas, Washington, and Wisconsin ; and, to the countries of Austria, Belgium, France, Germany, Ireland, Italy, Luxembourg, Netherlands and United Kingdom, Switzerland, and Qatar.",
      "recall_number": "Z-0482-2016",
      "product_description": "MicroCutter Xchange 30 Blue Cartridge, FG-025320;  The MicroCutter XCHANGE 30 Blue Cartridge and MicroCutter XCHANGE 30 Blue Curved Tip Cartridge contain 316L stainless steel staples. The cartridges are used with the MicroCutter XCHANGE 30 Stapler, which is a single patient device. When the MicroCutter XCHANGE 30 Stapler is loaded with a MicroCutter XCHANGE 30 Cartridge, two double rows of 316L stainless steel staples are delivered while simultaneously transecting tissue between the two, double staple rows. The MicroCutter XCHANGE 30 Stapler and MicroCutter XCHANGE 30 Cartridge are designed for introduction and use through a 5mm trocar cannula or larger.     Intended for use in multiple open or minimally invasive surgical procedures for the transaction, resection, and /or creation of anastomoses in small and large intestine as well as the transection of the appendix.",
      "product_quantity": "568 boxes or 6816 cartridges",
      "reason_for_recall": "Cardica, Inc. has received reports that use of the Blue Cartridges with the MicroCutter  XCHANGE 30 Stapler was associated with incomplete firing of staples, potentially resulting in an  incomplete transection or anastomosis of tissue during the surgical procedure.",
      "recall_initiation_date": "20151106",
      "center_classification_date": "20151224",
      "termination_date": "20160212",
      "report_date": "20151230",
      "code_info": "Lot numbers:  120416D  120521E  120606F  120613B  120621A  120910A  120926H  121005C  121022A  121031A  121119B  121217F  130131A  130207A  130213A  130220H  130227C  130307B  130320A  130328A  130426A  130508A  130516A  130619B  130613H  130716C  130815E  130822C  130911C  131003E  131113C  131125D  131212F  140109F  140115D  140127B  140204B  140226J  140304A  140310K  140317B  140325B  140430C  140507B  140604C  140610E  140617H  140624E  140707G  140710D  140715H  140804D  140819B  140828C  140916E  140922C  140926C  141008E  141016E  141103A  141106A  150415D  150625B  150813B  151006G"
    }
  ]
}