{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-04-22",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "country": "United States",
      "city": "Warsaw",
      "address_1": "345 E Main St",
      "reason_for_recall": "Zimmer Spine, Inc. is initiating a correction regarding the Trinica ALP Instrument Tray, part 07.01058.001 (all lots).  The Ratchet Handles, part 07.00438.001 may not be effectively sterilized if left in their designated location(s) in the instrument tray.  This is due to the current bracketing in the tray potentially interfering with complete steam penetration into the cannulated handle.",
      "address_2": "",
      "product_quantity": "94 Tray sets",
      "code_info": "Lots:  P060509, P061255, P070617, P080422, P090046",
      "center_classification_date": "20131118",
      "distribution_pattern": "Worldwide Distribution - USA (nationwide) and Internationally to Nationwide and OUS countries include:  Australia, Austria, Belgium, Canada, France, Germany, Italy, New Zealand, Spain, Switzerland, and the UK.",
      "state": "IN",
      "product_description": "Trinica Anterior Lumbar Plate (ALP) system, part 07.01058.001.  Non Sterile, Rx only. The Trinica Anterior Lumbar Plate System is a temporary supplemental fixation device consisting of a variety of shapes and sizes of plates and screws.  The Trinica Anterior Lumbar Plate System is used as an implant for the correction and stabilization of the spine.  This system provides temporary stabilization and augments the development of a solid spinal fusion.  Additionally, this system provides the surgeon with the ability to supplement an interbody device with anterior plate fixation.  The Trinica Anterior Lumbar Plate System components can be locked into a variety of configurations and each construct may be customized to individual cases. The plates are low profile and anatomically designed to provide optimal fit from either anterior or anterior-lateral approach.  This system also features anti-migration locking caps to help secure the fixation screws.  All Trinica Anterior Lumbar Plate System implant components are made from titanium alloy (Ti-6AI-4V).  The Trinica Anterior Lumbar Plate System is indicated for use via the lateral or anterolateral surgical approach above the bifurcation of the great vessels or via the anterior surgical approach, below the bifurcation of the great vessels. This system is indicated in the treatment of lumbar or lumbosacral (L1-SI) spine instability as a result of fracture (including dislocation and subluxation), tumor, degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), pseudoarthrosis, spondylolisthesis, scoliosis, lordotic deformities of the spine, spinal stenosis, or a failed previous fusion.",
      "report_date": "20131127",
      "classification": "Class II",
      "openfda": {},
      "recalling_firm": "Zimmer, Inc.",
      "recall_number": "Z-0357-2014",
      "initial_firm_notification": "Letter",
      "product_type": "Devices",
      "event_id": "66439",
      "termination_date": "20150224",
      "more_code_info": "",
      "recall_initiation_date": "20131009",
      "postal_code": "46580-2746",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "status": "Terminated"
    }
  ]
}