  "results": [
    {
      "status": "Terminated",
      "city": "Waukesha",
      "state": "WI",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "72301",
      "recalling_firm": "GE Healthcare",
      "address_1": "3000 N Grandview Blvd",
      "address_2": "N/A",
      "postal_code": "53188-1615",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "Worldwide Distribution - US: Nationwide including DC, PR and GU and the countries of ALGERIA, ARGENTINA, AUSTRALIA, AUSTRIA, AZERBAIJAN, BAHRAIN, BELARUS, BELGIUM, BERMUDA, BOSNIA HERZEGOVINA, BRAZIL, BULGARIA, CANADA, CHINA, CZECH REPUBLIC, DENMARK, EGYPT, ESTONIA, ETHIOPIA, FINLAND, FRANCE, GERMANY, GREECE, HONG Kong, HUNGARY, INDIA, INDONESIA, IRAN, IRELAND, ISRAEL, ITALY, JAMAICA, JAPAN, KAZAKHSTAN, REPUBLIC OF KOREA, KUWAIT, LEBANON, LUXEMBOURG, MALAYSIA, MEXICO, NETHERLANDS, NEW ZEALAND, NORWAY, PERU, POLAND, PORTUGAL, QATAR, ROMANIA, RUSSIA, SAUDI ARABIA, SERBIA, SINGAPORE, SLOVENIA, SOUTH AFRICA, SPAIN, SWEDEN, SWITZERLAND, SYRIA, TAIWAN, THAILAND, TURKEY, UNITED ARAB EMIRATES, UNITED KINGDOM, URUGUAY, and VENEZUELA.",
      "recall_number": "Z-0256-2016",
      "product_description": "GE Healthcare, SIGNA Excite 3.0T.  MR System for use as a diagnostic imaging device.",
      "product_quantity": "55",
      "reason_for_recall": "When performing head or neck scans, the currently displayed SAR values could be lower than the actual SAR in the head as predicted by SAR modeling. The predicted HEAD SAR value from the modeling suggests the actual SAR in the head could exceed IEC60601-2-33 limit of 3.2 W/kg for some scans.",
      "recall_initiation_date": "20150831",
      "center_classification_date": "20151109",
      "termination_date": "20180907",
      "report_date": "20151118",
      "code_info": "00000304469MR0 910609CF3T  00000000043586 336713WFUMR  002004-0924-11 321MR3T3  2333 901726OPMR  002004-0520-05 727785MR  00000005232YR4 414649MR5  000000HDMR2722 858657MR1  1556044 9085223T  002004-0520-06 407999MR3T  002004-0805-01 8109873T  00000263655MR3 321MR3T2  00000006583YR9 HSS3T5  002005-0216-15 731425MR2  002005-0216-19 6053883T  002005-1020-30 248465MR3T  002005-0127-12 248849MR3T  002004-1117-11 916UCDMR3T  000000HDMR3737 2059393T  002005-0331-11 919684MR6  000000HDMR3654 402219MR3T  002005-0519-19 205345MR3T  000000000R3780 210921SWGMR  002005-1201-36 662MSU3T  000000HDMR5675 407303MR3T  00000267527MR0 903870VM3TMR1  000000HDMR5786 602285MR4  00000HDMR10672 ASLWEST30MR  00000269041MR0 0910272044  00000266160MR1 2550000  00000257756MR7 082427230015  00000279423MR8 082427310015  00000280319MR5 082427160051  00000280898MR8 082427100075  00000282686MR5 082427010032  00000283076MR8 082427300008  00000283386MR1 082427070048  00000265969MR6 082427040042  00000279752MR0 082427160050  00000273833MR4 M4434864  00000264643MR8 M4135138  00000838BD4EC9 A5103135  00000273267MR5 YM1408  00000267200MR4 YM1396  00000267203MR8 YM1397  00000268417MR3 YM1414  00000269575MR7 YM1403  00000270026MR8 YM1405  00000272070MR4 YM1407  00000272969MR7 YM1406  00000260692MR9 0850270170  000000HDMR3167 81MR3T2715363  00000013212GQ6 7771MREXCITE3  00000254375MR9 NPV26104  00000266826MR7 0853270071  00000269581MR5 0853270072"
    }
  ]
}