{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-04-01",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "status": "Ongoing",
      "city": "Santa Ana",
      "state": "CA",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "88720",
      "recalling_firm": "Fujifilm Irvine Scientific, Inc.",
      "address_1": "2511 Daimler St",
      "address_2": "N/A",
      "postal_code": "92705-5533",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "E-Mail",
      "distribution_pattern": "Worldwide Distribution: U.S. (nationwide) to states of: AL, AK, AZ, CA, CT, DE, FL, ID, IL, IN, ND, NC, NV, NY, NJ, NE, OH, OK, OR, PA, SC, SD, MA, MS, MI, MO, MD, MN, TN, TX, UT, VA, VT, WI, WV and OUS (international) to countries of: Brazil, EU, Canada, India, South Korea, and Singapore.",
      "recall_number": "Z-0249-2022",
      "product_description": "Vit Kit-Freeze is intended for use in assisted reproductive procedures for vitrification and storage of human oocytes (MII), pronuclear (PN) zygotes through day 3 cleavage stage embryos and blastocyst stage embryos. This kit is designed for use with CryoTip (Catalog #40709), and Vitrification Thaw Kit (Vit Kit-Thaw) for optimal recovery of specimens.  Vitrification Freeze kit (which includes the VS Vitrification Solution) are cryopreservation media intended for use in the vitrification of oocytes (MII) and pronuclear (PN) zygotes, cleavage stage embryos, and blastocyst stage embryos.  Catalog numbers: 90133-SO Vitrification Freeze kit, contained 9x1 mL. Vitrification solution, VS, Catalog #90132. Product form: Liquid.  Equilibration Solution-ES is a HEPES buffered solution of Medium-199 containing gentamicin sulfate, 7.5% (v/v) of each DMSO and ethylene glycol and 20% (v/v) Dextran Serum Supplement (DSS). Vitrification Solution-VS is a HEPES buffered solution of Medium-199 containing gentamicin sulfate, 15% (v/v) of each DMSO and ethylene glycol, 20% (v/v) DSS and 0.5 M sucrose. DSS is a protein supplement consisting of 50 mg/mL therapeutic grade Human Serum Albumin (HSA) and 20 mg/mL Dextran. DSS is used at 20% (v/v) in Vit Kit-Freeze for a final concentration of 10 mg/mL HSA and 4 mg/mL Dextran. These two solutions are to be used in sequence according to the step-wise microdrop vitrification protocol. Vitrification Solution-VS Aseptically filtered. Test results reported on C of A Vit Kit -Freeze (Vitrification Freeze Kit) with Gentamycin and DSS Contains 2 x 1 mL Equilibration Solution- ES; 2 X 1 mL Vitrification Solution-VS ...90133-DCOS...RX Only...Sterile ...20YY-MM-DD",
      "product_quantity": "3981 units of Vitrification Freeze Kit 90133-SO210605; 314 kits in U.S. and 3667 OUS",
      "reason_for_recall": "Due to a component in kit being labeled with the incorrect Expiration Date",
      "recall_initiation_date": "20210908",
      "center_classification_date": "20211117",
      "report_date": "20211124",
      "code_info": "Catalog number: 90133-SO Vitrification Freeze kit Lot/Unit numbers: 90132210403; UDI # 00893727002811 Product code MLQ",
      "more_code_info": ""
    }
  ]
}