  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-04-22",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "country": "United States",
      "city": "Rochester",
      "address_1": "150 Verona St",
      "reason_for_recall": "Carestream Health, Inc. has issued a recall when using the CARESTREAM Client Workstation where under very specific conditions, some images from multi-slice studies such as CT and MR may not load into the viewer application due to a software problem.",
      "address_2": "",
      "product_quantity": "",
      "code_info": "Model: Vue PACS client version 11.3.2.0 / 11.3.2.4 / 11.4  Catalog Number: 8230633",
      "center_classification_date": "20131113",
      "distribution_pattern": "Worldwide Distribution - USA including AR, AZ, CA, CO, CT, FL, IA, IL, MA, MD, ME, MN, MO, NC, NH, NV, NY, OH, OK, PA, RI, TN, UT, VA WA, and WI and Internationally to Canada, Japan, and Kuwait.",
      "state": "NY",
      "product_description": "Carestream Vue PACS; Virtual PWR Reading Basic SW StandAlone  The CARESTREAM PACS is an image management system whose intended use is to provide completely scaleable local and wide area PACS solutions for hospital and related institutions/sites, which will archive, distribute, retrieve and display images and data from all hospital modalities and information systems.",
      "report_date": "20131120",
      "classification": "Class II",
      "openfda": {},
      "recalling_firm": "Carestream Health Inc.",
      "recall_number": "Z-0220-2014",
      "initial_firm_notification": "Letter",
      "product_type": "Devices",
      "event_id": "66306",
      "termination_date": "20151221",
      "more_code_info": "",
      "recall_initiation_date": "20130916",
      "postal_code": "14608-1733",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "status": "Terminated"
    }
  ]
}