  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-04-15",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "status": "Terminated",
      "city": "Billings",
      "state": "MT",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "71968",
      "recalling_firm": "Windstone Medical Packaging, Inc.",
      "address_1": "1602 4th Ave N",
      "address_2": "N/A",
      "postal_code": "59101-1521",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "Nationwide Distribution to California, Florida, Georgia, Illinois, Kansas, Louisiana, Michigan, New Jersey, Nevada, Texas, Virginia, and Wyoming.",
      "recall_number": "Z-0205-2017",
      "product_description": "Hand Tray\tPSS2365(A, PSS2365(B, PSS2365(C, PSS2365(D  PSS2365(E,   convenience custom kits used for general surgery in hospital operating room",
      "product_quantity": "3444 kits",
      "reason_for_recall": "The Medtronic COVER LIGHT HANDLE DISPOSABLE GLOVES, Part # 13140, of the custom AMS kit were recalled because gloves may contain splits or holes compromising sterility.",
      "recall_initiation_date": "20150422",
      "center_classification_date": "20161020",
      "termination_date": "20161025",
      "report_date": "20161026",
      "code_info": "Lot numbers/Expiration dates:    62742 2/28/2014  65112 3/23/2014  65816 4/24/2014  56706 5/15/2014  66648 7/21/2014  66649 7/21/2014  66165 7/25/2014  57524 9/1/2014  57338 9/20/2014  57977 9/22/2014  56883 9/24/2014  57057 9/24/2014  57523 9/25/2014  58348 1/3/2015  58349 1/4/2015  59680 1/17/2015  60694 1/24/2015  59678 1/25/2015  59679 1/26/2015  59221 1/28/2015  60104 1/29/2015  61738 4/24/2015  61740 6/11/2015  64688 6/19/2015  63590 6/22/2015  63772 6/22/2015  64002 6/22/2015  61739 6/27/2015  63257 6/28/2015  67941 2/11/2016  69813 3/23/2016  69812 3/26/2016  70306 3/30/2016  70581 3/30/2016  68432 6/1/2016  68433 6/9/2016  68006 6/12/2016  68578 6/13/2016  68008 6/30/2016  68894 6/30/2016  75064 7/30/2016  75200 7/30/2016  75500 7/30/2016  75803 7/30/2016  71902 9/10/2016  70989 9/21/2016  72308 9/24/2016  72754 9/24/2016  71238 9/25/2016  74820 11/9/2016  73337 11/15/2016  73397 11/15/2016  74294 11/24/2016  72983 11/25/2016  73566 11/28/2016  78172 4/16/2017  78171 4/19/2017  77607 4/23/2017  76467 4/24/2017  77068 4/24/2017  78380 4/24/2017  80630 4/24/2017  79474 4/25/2017"
    }
  ]
}