      "status": "Ongoing",
      "city": "Itabashi",
      "state": "N/A",
      "country": "Japan",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "92999",
      "recalling_firm": "DKK Dai-Ichi Shomei Co., Ltd.",
      "address_1": "1 Chome 32-26",
      "address_2": "Sakashita",
      "postal_code": "N/A",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "US States: MI",
      "recall_number": "Z-0072-2024",
      "product_description": "LFS Flat screen support arm systems without surgical lamp for models Aurora series, Aurora 2 series, Aurora 3 series, Aurora 4 series, Aurora Astro series, Stellar XL, and Stellar series, LFS Flat Screen Support Arm Model Numbers",
      "product_quantity": "1211 units",
      "reason_for_recall": "The stopper block on the LFS bracket could be broken or missing. Without this stopper block, the flat screen attached to the LFS flat screen system can rotate beyond the original angle limit and it could cause excessive force to be given to the spring shaft of the LFS bracket. Due to the excessive force given to the spring shaft, the spring shaft could break and shear off.",
      "recall_initiation_date": "20230823",
      "center_classification_date": "20231005",
      "report_date": "20231011",
      "code_info": "Serial Numbers: RA000006, RA000007, RA000008, RA000009, RA000010, RA000244, RA000245, RA000246, RA000247, RA000248, RA000359, RA000360, RA000361, RA000362, RA000363, RA000364, RA000365, RA000366, RA000367, RA000368, RA000391, RA000393, RA000408, RA000410, RA000412, RA000414, RA000416, RA000418, RA000374, RA000459, RA000648, RA000712, RA000714, RA000716, RA000718, RA000720, RA000722, RA000724, RA000726, RA000751, RA000752, RA000753, RA000754, RA000755, RA000756, RA000757, RA000905, RA000907, RA000909, RA000911, RA000916, RA000918, RA000920, RA000922, RA000924, RA000926, RA001136, RA001138, RA001144, RA001145, RA001146, RA001147, RA001148, RA001197, RA001198, RA001199, RA001200, RA001201, RA001202, RA001203, RA001204, RA001205, RA001206, RA001189, RA001190, RA001244, RA001246, RA001252, RA001253, RA001254, RA001255, RA001256, RA001257, RA001287, RA001288, RA001289, RA001290, RA001291, RA001292, RA001299, RA001300, RA001345, RA001347, RA001374, RA001376, RA001377, RA001378, RA001379, RA001380, RA001381, RA001382, RA001383, RA001384, RA001385, RA001386, RA001434, RA001435, RA001439, RA001469, RA001470, RA001471, RA001472, RA001473, RA001474, RA001475, RA001476, RA001479, RA001480, RA001503, RA001529, RA001553, RA001555, RA001572, RA001573, RA001574, RA001575, RA001585, RA001576, RA001588, RA001664, RA001665, RA001666, RA001668, RA001669, RA001670, RA001710, RA001711, RA001712, RA001713, RA001714, RA001729, RA001732, RA001708, RA001709, BM003066, BM003067, BM003068, BM003069, BM003136, BM003137, BM003138, BM003262, BM003263, BM003264, BM003265, BM003266, BM003267, BM003268, BM003269, BM003270, BM003271, BM003272, BM003295, BM003296, BM003297, BM003298, BM003299, BM003907, BM003908, BM003909, BM003910, BM003911, BM003912, BM003913, BM003914, BM003915, BM003916, BM003917, BM003423 - BM003426, BM003497 - BM003506, BM003605 - BM003606, BM003607 - BM003613, BM003866 - BM003867, BM004072 - BM004072, BM004125 - BM004130, BM004188 - BM004195, BM004392 - BM004401, BM004721 - BM004724, BM004705 - BM004720, BM004725 - BM004725, BM004981 - BM004990, BM005290 - BM005299, BM005428 - BM005432, BM005433 - BM005434, BM005640 - BM005645, BM005805 - BM005810, BM005948 - BM005949, BM006021 - BM006026, BM006113 - BM006118, BM006268 - BM006270, BM006453 - BM006464, BM006465 - BM006468, BM006575 - BM006580, BM006637 - BM006643, BM006644 - BM006646, BM006717 - BM006722, BM006790 - BM006791, BM006794 - BM006805, BM006792 - BM006793, BM007021 - BM007030, BM007031 - BM007036, BM007144 - BM007147, BM007239 - BM007244, BM007245 - BM007248, BM007359 - BM007364, BM007365 - BM007370, BM007502 - BM007507, BM007624 - BM007627, BM007800 - BM007807, BM007808 - BM007811, BM008045 - BM008054, BM008151 - BM008155, BM008206 - BM008215, BM008406 - BM008415, BM008577 - BM008586, BM008679 - BM008688, BM008739 - BM008748, BM009115 - BM009124, BM009393 - BM009402, BM009522 - BM009535, BM009542 - BM009542, BM009610 - BM009614, BM009615 - BM009624, BM009718 - BM009733, BM009734 - BM009738, BM009739 - BM009740, BM009741 - BM009744, BM009961 - BM009965, BM010144 - BM010148, BM010149 - BM010149, BM010541 - BM010545, BM010874 - BM010878, BM010939 - BM010939, BM011000 - BM011004, BM011172 - BM011176, BM011259 - BM011263, BM011447 - BM011451, BM011547 - BM011556, BM011740 - BM011754, BM011847 - BM011856, BM011927 - BM011936, BM012134 - BM012134, BM012047 - BM012056, BM012242 - BM012246, BM012247 - BM012251, BM012252 - BM012256, BM012352 - BM012356, BM012423 - BM012427, BM012430 - BM012439, BM012500 - BM012500, BM012636 - BM012645, BM012732 - BM012741, BM012862 - BM012871, BM013163 - BM013164, BM013159 - BM013162, BM013262 - BM013269, BM013355 - BM13359, BM013449 - BM13453, BM013632 - BM013632, BM013634 - BM013638, BM013804 - BM013808, BM013905 - BM013909, BM014076 - BM014077, BM014263 - BM014264, BM014253 - BM014262, BM014468 - BM014477, BM014629 - BM014633, BM014931 - BM014932, BM015038 - BM015042, BM015115 - BM015124, BM015175 - BM015184, BM015278 - BM015285, BM015286 - BM015289, BM015523 - BM015527, BM015653 - BM015657, BM015658 - BM015661, BM015857 - BM015861, BM016047 - BM016051, BM016054 - BM016055, BM016056 - BM016060, BM016401 - BM016402, BM016530 - BM016543, BM017090 - BM017091, BM017196 - BM017197, BM017303 - BM017306, BM017307 - BM017310, BM017386 - BM017389, BM017402 - BM017405, BM017442 - BM017445, BM017814 - BM017815, BM017816 - BM017817, BM017902 - BM017904, BM017963 - BM017966, BM017967 - BM017969, BM018102 - BM018103, BM018104 - BM018106, BM018185 - BM018187, BM018188 - BM018189, BM018243 - BM018245, BM018246 - BM018247, BM018248 - BM018249, BM018282 - BM018283, BM018370 - BM018374, BM018375 - BM018375, BM018447 - BM018450, BM018451 - BM018452, BM018474 - BM018476, BM018477 - BM018478, BM018479 - BM018480, BM018662 - BM018667, BM018668 - BM018669, BM018677 - BM018680, BM018681 - BM018682, BM018962 - BM018967, BM019058 - BM019061, BM019253 - BM019256, BM019348 - BM019352, BM019561 - BM019563, BM019674 - BM019676, BM019677 - BM019678, BM020498 - BM020499, BM020601 - BM020604, BM020704 - BM020705, BM020801 - BM020803, BM020899 - BM020900, BM020901 - BM020902, BM021002 - BM021003, BM021091 - BM021092, BM021183 - BM021184, BM021339 - BM021341, BM021730 - BM021733, BM021734 - BM021735, BM021823 - BM021824, BM021825 - BM021826, BM022127 - BM022128, BM022329 - BM022332, BM022416 - BM022417, BM022457 - BM022458, BM022533 - BM022534, BM022535 - BM022536, BM022537 - BM022538, BM022606 - BM022607, BM022608 - BM022609, BM022676 - BM022677, BM022678 - BM022681, BM022761 - BM022762, BM022830 - BM022833, BM022907 - BM022908, BM022909 - BM022911, BM022995 - BM022996, BM023075 - BM023076, BM023155 - BM023156, BM023157 - BM023158, BM023249 - BM023250, BM023331 - BM023332, BM023333 - BM023334, BM023398 - BM023400, BM023583 - BM023584, BM024411 - BM024412, BM024612 - BM024613, BM024643 - BM024645, BM025092 - BM025099, BM025349 - BM025351, BM025417 - BM025419, BM025420 - BM025421, BM025422, BM025940, BM025941 - BM025946, BM025947 - BM025948, BM026027 - BM026030, BM026281, BM026405, BM026879 - BM026884, BM027023 - BM027032, BM027081 - BM027085, BM027133 - BM027134, BM027135 - BM027136, BM027210, BM027211, BM027303 - BM027304, BM027477 - BM027478, BM027609 - BM027611, BM027737 - BM027738, BM027838, BM028212 - BM028214, BM028215 - BM028216, BM029320 - BM029325, BM029668 - BM029673"
    }
  ]
}